Phosphoric Acid Process Measurement
The phosphoric acid application software is designed to use the temperature and density information that comes from the CL10 HY cell to calculate product baumé, density at a reference temperature, specific gravity and percent concentration. Automation Products Inc. uses the same reference tables that are used by phosphoric acid manufacturers to cross check results generated by our phosphoric acid software.
The CL10 HY and Series 2000 combination have been used to measure phosphoric acid for chemical applications and low concentration acid mixing. It has also been used to measure high concentration phosphoric acid in acid make-up applications.
Dynatrol density cells can be supplied with tantalum media contact parts as well as carpenter 20, stainless steel and other alloys that can be chosen for your specific application.